1 <!-- Copyright (C) 2003 Red Hat, Inc. -->
2 <!-- This material may be distributed only subject to the terms -->
3 <!-- and conditions set forth in the Open Publication License, v1.0 -->
4 <!-- or later (the latest version is presently available at -->
5 <!-- http://www.opencontent.org/openpub/). -->
6 <!-- Distribution of the work or derivative of the work in any -->
7 <!-- standard (paper) book form is prohibited unless prior -->
8 <!-- permission is obtained from the copyright holder. -->
13 ><meta name="MSSmartTagsPreventParsing" content="TRUE">
16 CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
19 TITLE="eCos Reference Manual"
20 HREF="ecos-ref.html"><LINK
22 TITLE="Flash Image System (FIS)"
23 HREF="flash-image-system.html"><LINK
26 HREF="fis-init-command.html"><LINK
29 HREF="fis-free-command.html"></HEAD
40 SUMMARY="Header navigation table"
49 >eCos Reference Manual</TH
57 HREF="fis-init-command.html"
71 HREF="fis-free-command.html"
82 NAME="FIS-LIST-COMMAND">fis list</H1
90 >fis list -- List Flash Image System directory</DIV
92 CLASS="REFSYNOPSISDIV"
115 CLASS="INFORMALTABLE"
162 >Show image checksum instead of memory address
164 CLASS="COMPUTEROUTPUT"
169 CLASS="COMPUTEROUTPUT"
193 >Show image data length instead of amount of flash
194 occupied by image (column
196 CLASS="COMPUTEROUTPUT"
200 CLASS="COMPUTEROUTPUT"
223 >This command lists the images currently available in the FIS. Certain
224 images used by RedBoot have fixed names and have reserved slots in the
225 FIS (these can be seen after using the <B
229 command). Other images can be manipulated by the user.</P
237 >The images are listed in the order they appear in the FIS
238 directory, not by name or creation time.</P
250 >List the FIS directory.
266 Name FLASH addr Mem addr Length Entry point
267 RedBoot 0x00000000 0x00000000 0x00020000 0x00000000
268 RedBoot config 0x0007F000 0x0007F000 0x00001000 0x00000000
269 FIS directory 0x00070000 0x00070000 0x0000F000 0x00000000 </PRE
275 >List the FIS directory, with image checksums substituted for
292 Name FLASH addr Checksum Length Entry point
293 RedBoot 0x00000000 0x00000000 0x00020000 0x00000000
294 RedBoot config 0x0007F000 0x00000000 0x00001000 0x00000000
295 FIS directory 0x00070000 0x00000000 0x0000F000 0x00000000 </PRE
301 >List the FIS directory with image data lengths substituted for flash
302 block reservation lengths.
318 Name FLASH addr Mem addr Datalen Entry point
319 RedBoot 0x00000000 0x00000000 0x00000000 0x00000000
320 RedBoot config 0x0007F000 0x0007F000 0x00000000 0x00000000
321 FIS directory 0x00070000 0x00070000 0x00000000 0x00000000 </PRE
332 SUMMARY="Footer navigation table"
343 HREF="fis-init-command.html"
361 HREF="fis-free-command.html"
377 HREF="flash-image-system.html"