]> git.karo-electronics.de Git - karo-tx-linux.git/blob - drivers/net/Kconfig
Merge tag 'scsi-misc' of git://git.kernel.org/pub/scm/linux/kernel/git/jejb/scsi
[karo-tx-linux.git] / drivers / net / Kconfig
1 #
2 # Network device configuration
3 #
4
5 menuconfig NETDEVICES
6         default y if UML
7         depends on NET
8         bool "Network device support"
9         ---help---
10           You can say N here if you don't intend to connect your Linux box to
11           any other computer at all.
12
13           You'll have to say Y if your computer contains a network card that
14           you want to use under Linux. If you are going to run SLIP or PPP over
15           telephone line or null modem cable you need say Y here. Connecting
16           two machines with parallel ports using PLIP needs this, as well as
17           AX.25/KISS for sending Internet traffic over amateur radio links.
18
19           See also "The Linux Network Administrator's Guide" by Olaf Kirch and
20           Terry Dawson. Available at <http://www.tldp.org/guides.html>.
21
22           If unsure, say Y.
23
24 # All the following symbols are dependent on NETDEVICES - do not repeat
25 # that for each of the symbols.
26 if NETDEVICES
27
28 config MII
29         tristate
30
31 config NET_CORE
32         default y
33         bool "Network core driver support"
34         ---help---
35           You can say N here if you do not intend to use any of the
36           networking core drivers (i.e. VLAN, bridging, bonding, etc.)
37
38 if NET_CORE
39
40 config BONDING
41         tristate "Bonding driver support"
42         depends on INET
43         depends on IPV6 || IPV6=n
44         ---help---
45           Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
46           Channels together. This is called 'Etherchannel' by Cisco,
47           'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
48
49           The driver supports multiple bonding modes to allow for both high
50           performance and high availability operation.
51
52           Refer to <file:Documentation/networking/bonding.txt> for more
53           information.
54
55           To compile this driver as a module, choose M here: the module
56           will be called bonding.
57
58 config DUMMY
59         tristate "Dummy net driver support"
60         ---help---
61           This is essentially a bit-bucket device (i.e. traffic you send to
62           this device is consigned into oblivion) with a configurable IP
63           address. It is most commonly used in order to make your currently
64           inactive SLIP address seem like a real address for local programs.
65           If you use SLIP or PPP, you might want to say Y here. Since this
66           thing often comes in handy, the default is Y. It won't enlarge your
67           kernel either. What a deal. Read about it in the Network
68           Administrator's Guide, available from
69           <http://www.tldp.org/docs.html#guide>.
70
71           To compile this driver as a module, choose M here: the module
72           will be called dummy.
73
74 config EQUALIZER
75         tristate "EQL (serial line load balancing) support"
76         ---help---
77           If you have two serial connections to some other computer (this
78           usually requires two modems and two telephone lines) and you use
79           SLIP (the protocol for sending Internet traffic over telephone
80           lines) or PPP (a better SLIP) on them, you can make them behave like
81           one double speed connection using this driver.  Naturally, this has
82           to be supported at the other end as well, either with a similar EQL
83           Linux driver or with a Livingston Portmaster 2e.
84
85           Say Y if you want this and read
86           <file:Documentation/networking/eql.txt>.  You may also want to read
87           section 6.2 of the NET-3-HOWTO, available from
88           <http://www.tldp.org/docs.html#howto>.
89
90           To compile this driver as a module, choose M here: the module
91           will be called eql.  If unsure, say N.
92
93 config NET_FC
94         bool "Fibre Channel driver support"
95         depends on SCSI && PCI
96         help
97           Fibre Channel is a high speed serial protocol mainly used to connect
98           large storage devices to the computer; it is compatible with and
99           intended to replace SCSI.
100
101           If you intend to use Fibre Channel, you need to have a Fibre channel
102           adaptor card in your computer; say Y here and to the driver for your
103           adaptor below. You also should have said Y to "SCSI support" and
104           "SCSI generic support".
105
106 config IFB
107         tristate "Intermediate Functional Block support"
108         depends on NET_CLS_ACT
109         ---help---
110           This is an intermediate driver that allows sharing of
111           resources.
112           To compile this driver as a module, choose M here: the module
113           will be called ifb.  If you want to use more than one ifb
114           device at a time, you need to compile this driver as a module.
115           Instead of 'ifb', the devices will then be called 'ifb0',
116           'ifb1' etc.
117           Look at the iproute2 documentation directory for usage etc
118
119 source "drivers/net/team/Kconfig"
120
121 config MACVLAN
122         tristate "MAC-VLAN support"
123         ---help---
124           This allows one to create virtual interfaces that map packets to
125           or from specific MAC addresses to a particular interface.
126
127           Macvlan devices can be added using the "ip" command from the
128           iproute2 package starting with the iproute2-2.6.23 release:
129
130           "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
131
132           To compile this driver as a module, choose M here: the module
133           will be called macvlan.
134
135 config MACVTAP
136         tristate "MAC-VLAN based tap driver"
137         depends on MACVLAN
138         help
139           This adds a specialized tap character device driver that is based
140           on the MAC-VLAN network interface, called macvtap. A macvtap device
141           can be added in the same way as a macvlan device, using 'type
142           macvtap', and then be accessed through the tap user space interface.
143
144           To compile this driver as a module, choose M here: the module
145           will be called macvtap.
146
147 config VXLAN
148        tristate "Virtual eXtensible Local Area Network (VXLAN)"
149        depends on INET
150        select NET_IP_TUNNEL
151        select NET_UDP_TUNNEL
152        ---help---
153           This allows one to create vxlan virtual interfaces that provide
154           Layer 2 Networks over Layer 3 Networks. VXLAN is often used
155           to tunnel virtual network infrastructure in virtualized environments.
156           For more information see:
157             http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
158
159           To compile this driver as a module, choose M here: the module
160           will be called vxlan.
161
162 config NETCONSOLE
163         tristate "Network console logging support"
164         ---help---
165         If you want to log kernel messages over the network, enable this.
166         See <file:Documentation/networking/netconsole.txt> for details.
167
168 config NETCONSOLE_DYNAMIC
169         bool "Dynamic reconfiguration of logging targets"
170         depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
171                         !(NETCONSOLE=y && CONFIGFS_FS=m)
172         help
173           This option enables the ability to dynamically reconfigure target
174           parameters (interface, IP addresses, port numbers, MAC addresses)
175           at runtime through a userspace interface exported using configfs.
176           See <file:Documentation/networking/netconsole.txt> for details.
177
178 config NETPOLL
179         def_bool NETCONSOLE
180
181 config NET_POLL_CONTROLLER
182         def_bool NETPOLL
183
184 config NTB_NETDEV
185         tristate "Virtual Ethernet over NTB"
186         depends on NTB
187
188 config RIONET
189         tristate "RapidIO Ethernet over messaging driver support"
190         depends on RAPIDIO
191
192 config RIONET_TX_SIZE
193         int "Number of outbound queue entries"
194         depends on RIONET
195         default "128"
196
197 config RIONET_RX_SIZE
198         int "Number of inbound queue entries"
199         depends on RIONET
200         default "128"
201
202 config TUN
203         tristate "Universal TUN/TAP device driver support"
204         select CRC32
205         ---help---
206           TUN/TAP provides packet reception and transmission for user space
207           programs.  It can be viewed as a simple Point-to-Point or Ethernet
208           device, which instead of receiving packets from a physical media,
209           receives them from user space program and instead of sending packets
210           via physical media writes them to the user space program.
211
212           When a program opens /dev/net/tun, driver creates and registers
213           corresponding net device tunX or tapX.  After a program closed above
214           devices, driver will automatically delete tunXX or tapXX device and
215           all routes corresponding to it.
216
217           Please read <file:Documentation/networking/tuntap.txt> for more
218           information.
219
220           To compile this driver as a module, choose M here: the module
221           will be called tun.
222
223           If you don't know what to use this for, you don't need it.
224
225 config VETH
226         tristate "Virtual ethernet pair device"
227         ---help---
228           This device is a local ethernet tunnel. Devices are created in pairs.
229           When one end receives the packet it appears on its pair and vice
230           versa.
231
232 config VIRTIO_NET
233         tristate "Virtio network driver"
234         depends on VIRTIO
235         select AVERAGE
236         ---help---
237           This is the virtual network driver for virtio.  It can be used with
238           lguest or QEMU based VMMs (like KVM or Xen).  Say Y or M.
239
240 config NLMON
241         tristate "Virtual netlink monitoring device"
242         ---help---
243           This option enables a monitoring net device for netlink skbs. The
244           purpose of this is to analyze netlink messages with packet sockets.
245           Thus applications like tcpdump will be able to see local netlink
246           messages if they tap into the netlink device, record pcaps for further
247           diagnostics, etc. This is mostly intended for developers or support
248           to debug netlink issues. If unsure, say N.
249
250 endif # NET_CORE
251
252 config SUNGEM_PHY
253         tristate
254
255 source "drivers/net/arcnet/Kconfig"
256
257 source "drivers/atm/Kconfig"
258
259 source "drivers/net/caif/Kconfig"
260
261 source "drivers/net/dsa/Kconfig"
262
263 source "drivers/net/ethernet/Kconfig"
264
265 source "drivers/net/fddi/Kconfig"
266
267 source "drivers/net/hippi/Kconfig"
268
269 config NET_SB1000
270         tristate "General Instruments Surfboard 1000"
271         depends on PNP
272         ---help---
273           This is a driver for the General Instrument (also known as
274           NextLevel) SURFboard 1000 internal
275           cable modem. This is an ISA card which is used by a number of cable
276           TV companies to provide cable modem access. It's a one-way
277           downstream-only cable modem, meaning that your upstream net link is
278           provided by your regular phone modem.
279
280           At present this driver only compiles as a module, so say M here if
281           you have this card. The module will be called sb1000. Then read
282           <file:Documentation/networking/README.sb1000> for information on how
283           to use this module, as it needs special ppp scripts for establishing
284           a connection. Further documentation and the necessary scripts can be
285           found at:
286
287           <http://www.jacksonville.net/~fventuri/>
288           <http://home.adelphia.net/~siglercm/sb1000.html>
289           <http://linuxpower.cx/~cable/>
290
291           If you don't have this card, of course say N.
292
293 source "drivers/net/phy/Kconfig"
294
295 source "drivers/net/plip/Kconfig"
296
297 source "drivers/net/ppp/Kconfig"
298
299 source "drivers/net/slip/Kconfig"
300
301 source "drivers/s390/net/Kconfig"
302
303 source "drivers/net/usb/Kconfig"
304
305 source "drivers/net/wireless/Kconfig"
306
307 source "drivers/net/wimax/Kconfig"
308
309 source "drivers/net/wan/Kconfig"
310
311 source "drivers/net/ieee802154/Kconfig"
312
313 config XEN_NETDEV_FRONTEND
314         tristate "Xen network device frontend driver"
315         depends on XEN
316         select XEN_XENBUS_FRONTEND
317         default y
318         help
319           This driver provides support for Xen paravirtual network
320           devices exported by a Xen network driver domain (often
321           domain 0).
322
323           The corresponding Linux backend driver is enabled by the
324           CONFIG_XEN_NETDEV_BACKEND option.
325
326           If you are compiling a kernel for use as Xen guest, you
327           should say Y here. To compile this driver as a module, chose
328           M here: the module will be called xen-netfront.
329
330 config XEN_NETDEV_BACKEND
331         tristate "Xen backend network device"
332         depends on XEN_BACKEND
333         help
334           This driver allows the kernel to act as a Xen network driver
335           domain which exports paravirtual network devices to other
336           Xen domains. These devices can be accessed by any operating
337           system that implements a compatible front end.
338
339           The corresponding Linux frontend driver is enabled by the
340           CONFIG_XEN_NETDEV_FRONTEND configuration option.
341
342           The backend driver presents a standard network device
343           endpoint for each paravirtual network device to the driver
344           domain network stack. These can then be bridged or routed
345           etc in order to provide full network connectivity.
346
347           If you are compiling a kernel to run in a Xen network driver
348           domain (often this is domain 0) you should say Y here. To
349           compile this driver as a module, chose M here: the module
350           will be called xen-netback.
351
352 config VMXNET3
353         tristate "VMware VMXNET3 ethernet driver"
354         depends on PCI && INET
355         help
356           This driver supports VMware's vmxnet3 virtual ethernet NIC.
357           To compile this driver as a module, choose M here: the
358           module will be called vmxnet3.
359
360 source "drivers/net/hyperv/Kconfig"