@@ -8,6 +8,11 @@ Supported chips:
     Datasheets:
        http://www.ti.com/lit/gpn/lm25056
        http://www.ti.com/lit/gpn/lm25056a
+  * TI LM25063
+    Prefix: 'lm25063'
+    Addresses scanned: -
+    Datasheet:
+       To be announced
   * National Semiconductor LM25066
     Prefix: 'lm25066'
     Addresses scanned: -
@@ -32,7 +37,7 @@ Description
 -----------
 
 This driver supports hardware montoring for National Semiconductor / TI LM25056,
-LM25066, LM5064, and LM5064 Power Management, Monitoring, Control, and
+LM25063, LM25066, LM5064, and LM5066 Power Management, Monitoring, Control, and
 Protection ICs.
 
 The driver is a client driver to the core PMBus driver. Please see
@@ -64,8 +69,12 @@ in1_input            Measured input voltage.
 in1_average            Average measured input voltage.
 in1_min                        Minimum input voltage.
 in1_max                        Maximum input voltage.
+in1_crit               Critical high input voltage (LM25063 only).
+in1_lcrit              Critical low input voltage (LM25063 only).
 in1_min_alarm          Input voltage low alarm.
 in1_max_alarm          Input voltage high alarm.
+in1_lcrit_alarm                Input voltage critical low alarm (LM25063 only).
+in1_crit_alarm         Input voltage critical high alarm. (LM25063 only).
 
 in2_label              "vmon"
 in2_input              Measured voltage on VAUX pin
@@ -80,12 +89,16 @@ in3_input           Measured output voltage.
 in3_average            Average measured output voltage.
 in3_min                        Minimum output voltage.
 in3_min_alarm          Output voltage low alarm.
+in3_highest            Historical minimum output voltage (LM25063 only).
+in3_lowest             Historical maximum output voltage (LM25063 only).
 
 curr1_label            "iin"
 curr1_input            Measured input current.
 curr1_average          Average measured input current.
 curr1_max              Maximum input current.
+curr1_crit             Critical input current (LM25063 only).
 curr1_max_alarm                Input current high alarm.
+curr1_crit_alarm       Input current critical high alarm (LM25063 only).
 
 power1_label           "pin"
 power1_input           Measured input power.
@@ -95,6 +108,11 @@ power1_alarm                Input power alarm
 power1_input_highest   Historical maximum power.
 power1_reset_history   Write any value to reset maximum power history.
 
+power2_label           "pout". LM25063 only.
+power2_input           Measured output power.
+power2_max             Maximum output power limit.
+power2_crit            Critical output power limit.
+
 temp1_input            Measured temperature.
 temp1_max              Maximum temperature.
 temp1_crit             Critical high temperature.