hrtimer: timeout too long when using HRTIMER_CB_SOFTIRQ
commit
d7b41a24bfb5d7fa02f7b49be1293d468814e424 upstream
When using hrtimer with timer->cb_mode == HRTIMER_CB_SOFTIRQ
in some cases the clockevent is not programmed.
This happens, if:
- a timer is rearmed while it's state is HRTIMER_STATE_CALLBACK
- hrtimer_reprogram() returns -ETIME, when it is called after
CALLBACK is finished. This occurs if the new timer->expires
is in the past when CALLBACK is done.
In this case, the timer needs to be removed from the tree and put
onto the pending list again.
The patch is against 2.6.22.5, but AFAICS, it is relevant
for 2.6.25 also (in run_hrtimer_pending()).
Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com>
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>