mtd: get the ECC info from the Extended Parameter Page
Since the ONFI 2.1, the onfi spec adds the Extended Parameter Page
to store the ECC info.
The onfi spec tells us that if the nand chip's recommended ECC codeword
size is not 512 bytes, then the @ecc_bits is 0xff. The host _SHOULD_ then
read the Extended ECC information that is part of the extended parameter
page to retrieve the ECC requirements for this device.
This patch implement the reading of the Extended Parameter Page, and parses
the sections for ECC type, and get the ECC info from the ECC section.
Tested this patch with Micron MT29F64G08CBABAWP.
Acked-by: Pekon Gupta <pekon@ti.com> Signed-off-by: Huang Shijie <b32955@freescale.com> Reviewed-and-tested-by: Brian Norris <computersforpeace@gmail.com> Signed-off-by: Brian Norris <computersforpeace@gmail.com> Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>