]> git.karo-electronics.de Git - linux-beck.git/commit
Thermal: Introduce cooling states range support
authorZhang Rui <rui.zhang@intel.com>
Tue, 26 Jun 2012 08:27:22 +0000 (16:27 +0800)
committerZhang Rui <rui.zhang@intel.com>
Mon, 24 Sep 2012 06:44:36 +0000 (14:44 +0800)
commit74051ba50583a5880d4536c1d9333e2493ddfd76
tree9f1921db6d455ac7503fab3f46d0c46ea1b88f99
parente3f25e6e5836c4790fbe395ff42e241f372d859d
Thermal: Introduce cooling states range support

As the active cooling devices can have multiple cooling states,
we may want only several cooling states for a certain trip point,
and other cooling states for other active trip points.

To do this, we should be able to describe the cooling device
behavior for a certain trip point, rather than for the entire thermal zone.
And when updating thermal zone, we need to check the upper and lower limit
to make sure the cooling device is set to the proper cooling state.

Note that this patch will not bring any different behavior as
upper limit is set to max_state and lower limit is set to 0
in this patch, for now.

Next patch will set these to real values.

Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Reviewed-by: Rafael J. Wysocki <rjw@sisk.pl>
Reviewed-by: Eduardo Valentin <eduardo.valentin@ti.com>
drivers/thermal/thermal_sys.c