]> git.karo-electronics.de Git - linux-beck.git/commit
Merge branch 'mv88e6xxx-rework-reset-and-PPU-code'
authorDavid S. Miller <davem@davemloft.net>
Tue, 6 Dec 2016 16:32:29 +0000 (11:32 -0500)
committerDavid S. Miller <davem@davemloft.net>
Tue, 6 Dec 2016 16:32:29 +0000 (11:32 -0500)
commitb1df0f5ceab3cf0207dcb585c51424fe1bb1e1d2
treee118cf13a0d5a96ea0c57b6b42084df79996bd2b
parent9f9ffdffe9112abae781e5f4b44e7d2bc96aa6d5
parenta199d8b6956f8973d09d684fc71300889c26e8e4
Merge branch 'mv88e6xxx-rework-reset-and-PPU-code'

Vivien Didelot says:

====================
net: dsa: mv88e6xxx: rework reset and PPU code

Old Marvell chips (like 88E6060) don't have a PHY Polling Unit (PPU).

Next chips (like 88E6185) have a PPU, which has exclusive access to the
PHY registers, thus must be disabled before access.

Newer chips (like 88E6352) have an indirect mechanism to access the PHY
registers whenever, thus loose control over the PPU (always enabled).

Here's a summary:

Model | PPU? | Has PPU ctrl?  | PPU state readable? | PHY access
----- | ---- | -------------- | ------------------- | ----------
 6060 | no   | no             | no                  | direct
 6185 | yes  | yes, PPUEn bit | yes, PPUState 2-bit | direct w/ PPU dis.
 6352 | yes  | no             | yes, PPUState 1-bit | indirect
 6390 | yes  | no             | yes, InitState bit  | indirect

Depending on the PPU control, a switch may have to restart the PPU when
resetting the switch. Once the switch is reset, we must wait for the PPU
state to be active polling again before accessing the registers.

For that purpose, add new operations to the chips to enable/disable the
PPU, and execute software reset. With these new ops in place, rework the
switch reset code and finally get rid of the MV88E6XXX_FLAG_PPU* flags.

Changes in v3:
  - consider 6097 as 6352 (no PPU ops and use mv88e6352_g1_reset).

Changes in v2:
  - wait in ppu/reset ops so that ppu_polling is not needed anymore.
====================

Signed-off-by: David S. Miller <davem@davemloft.net>