The Zynq UART is Cadence IP and the driver has been renamed accordingly.
Migrate the DT to use the new binding for the UART driver.
Signed-off-by: Soren Brinkmann <soren.brinkmann@xilinx.com>
Acked-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Acked-by: Rob Herring <robh@kernel.org>
Tested-by: Michal Simek <michal.simek@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
};
uart0: serial@e0000000 {
};
uart0: serial@e0000000 {
- compatible = "xlnx,xuartps";
+ compatible = "xlnx,xuartps", "cdns,uart-r1p8";
status = "disabled";
clocks = <&clkc 23>, <&clkc 40>;
status = "disabled";
clocks = <&clkc 23>, <&clkc 40>;
- clock-names = "ref_clk", "aper_clk";
+ clock-names = "uart_clk", "pclk";
reg = <0xE0000000 0x1000>;
interrupts = <0 27 4>;
};
uart1: serial@e0001000 {
reg = <0xE0000000 0x1000>;
interrupts = <0 27 4>;
};
uart1: serial@e0001000 {
- compatible = "xlnx,xuartps";
+ compatible = "xlnx,xuartps", "cdns,uart-r1p8";
status = "disabled";
clocks = <&clkc 24>, <&clkc 41>;
status = "disabled";
clocks = <&clkc 24>, <&clkc 41>;
- clock-names = "ref_clk", "aper_clk";
+ clock-names = "uart_clk", "pclk";
reg = <0xE0001000 0x1000>;
interrupts = <0 50 4>;
};
reg = <0xE0001000 0x1000>;
interrupts = <0 50 4>;
};