]> git.karo-electronics.de Git - linux-beck.git/commitdiff
Documentation: devicetree: Add property for controlling power saving mode for the...
authorAdriana Reus <adriana.reus@intel.com>
Tue, 24 Nov 2015 10:59:49 +0000 (12:59 +0200)
committerJonathan Cameron <jic23@kernel.org>
Wed, 2 Dec 2015 18:42:03 +0000 (18:42 +0000)
Add a property to allow changing the default power-saving mode.
By default, at read raw the chip will activate and provide
one measurent, then it will shut itself down. However, the
chip can also work in "continuous" mode which may be more reliable
but is also more power consuming.

Signed-off-by: Adriana Reus <adriana.reus@intel.com>
Acked-by: Rob Herring <robh@kernel.org>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Documentation/devicetree/bindings/iio/light/us5182d.txt

index 6f0a530144fde8c2570ece125acdaa06aca22a4b..a61979997f373c6e784865dbf5fe145fd388906e 100644 (file)
@@ -7,13 +7,24 @@ Required properties:
 Optional properties:
 - upisemi,glass-coef: glass attenuation factor - compensation factor of
                       resolution 1000 for material transmittance.
+
 - upisemi,dark-ths: array of 8 elements containing 16-bit thresholds (adc
                     counts) corresponding to every scale.
+
 - upisemi,upper-dark-gain: 8-bit dark gain compensation factor(4 int and 4
                            fractional bits - Q4.4) applied when light > threshold
+
 - upisemi,lower-dark-gain: 8-bit dark gain compensation factor(4 int and 4
                            fractional bits - Q4.4) applied when light < threshold
 
+- upisemi,continuous: This chip has two power modes: one-shot (chip takes one
+                      measurement and then shuts itself down) and continuous (
+                      chip takes continuous measurements). The one-shot mode is
+                      more power-friendly but the continuous mode may be more
+                      reliable. If this property is specified the continuous
+                      mode will be used instead of the default one-shot one for
+                      raw reads.
+
 If the optional properties are not specified these factors will default to the
 values in the below example.
 The glass-coef defaults to no compensation for the covering material.