]> git.karo-electronics.de Git - linux-beck.git/commitdiff
iio: adc: twl4030_madc: Fix calculation of the temperature sense current
authorH. Nikolaus Schaller <hns@goldelico.com>
Thu, 28 May 2015 19:50:18 +0000 (21:50 +0200)
committerJonathan Cameron <jic23@kernel.org>
Sun, 7 Jun 2015 16:24:44 +0000 (17:24 +0100)
The bit mask to read the setting of the constant current source
for measuring the NTC voltage was the wrong one. Since default
value is initialized to the lowest level (000 = 10uA) the difference
was probably never noticed in practice.

Signed-off-by: H. Nikolaus Schaller <hns@goldelico.com>
Signed-off-by: Marek Belisko <marek@goldelico.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
drivers/iio/adc/twl4030-madc.c

index 94c5f05b4bc1b5ff64fc26dd4825496c706cd4a2..6d2d429a48e01c61ca228298c1f5aea3c71901c6 100644 (file)
@@ -235,7 +235,7 @@ static int twl4030battery_temperature(int raw_volt)
        if (ret < 0)
                return ret;
 
-       curr = ((val & TWL4030_BCI_ITHEN) + 1) * 10;
+       curr = ((val & TWL4030_BCI_ITHSENS) + 1) * 10;
        /* Getting and calculating the thermistor resistance in ohms */
        res = volt * 1000 / curr;
        /* calculating temperature */