The auto cmd settings bits should be cleared before sending new commands
or we may receive command timeout error for normal commands due to wrongly
pre-sent auto cmd.
e.g. we receive CMD13 timeout error due to ACMD23 is wrongly enabled
by former data commands.
mmc2: new high speed DDR MMC card at address 0001
mmcblk1: mmc2:0001 SEM08G 7.39 GiB
mmcblk1boot0: mmc2:0001 SEM08G partition 1 2.00 MiB
mmcblk1boot1: mmc2:0001 SEM08G partition 2 2.00 MiB
mmcblk1rpmb: mmc2:0001 SEM08G partition 3 128 KiB
mmcblk1: p1 p2 p3 p4 < p5 p6 p7 >
mmc2: Timeout waiting for hardware interrupt.
mmcblk1boot1: unknown partition table
mmc2: Timeout waiting for hardware interrupt.
mmcblk1boot0: unknown partition table
Signed-off-by: Dong Aisheng <b29396@freescale.com>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Chris Ball <cjb@laptop.org>
u16 mode;
struct mmc_data *data = cmd->data;
- if (data == NULL)
+ if (data == NULL) {
+ /* clear Auto CMD settings for no data CMDs */
+ mode = sdhci_readw(host, SDHCI_TRANSFER_MODE);
+ sdhci_writew(host, mode & ~(SDHCI_TRNS_AUTO_CMD12 |
+ SDHCI_TRNS_AUTO_CMD23), SDHCI_TRANSFER_MODE);
return;
+ }
WARN_ON(!host->data);