INT_CTL register contains bits INT_POL0 and INT_POL1, and not INT_POL.
This patch fixes the wrong register setting for INT_CTL.
Signed-off-by: Ajay Kumar <ajaykumar.rs@samsung.com>
Signed-off-by: Jingoo Han <jg1.han@samsung.com>
void exynos_dp_init_interrupt(struct exynos_dp_device *dp)
{
/* Set interrupt pin assertion polarity as high */
- writel(INT_POL, dp->reg_base + EXYNOS_DP_INT_CTL);
+ writel(INT_POL1 | INT_POL0, dp->reg_base + EXYNOS_DP_INT_CTL);
/* Clear pending regisers */
writel(0xff, dp->reg_base + EXYNOS_DP_COMMON_INT_STA_1);
/* EXYNOS_DP_INT_CTL */
#define SOFT_INT_CTRL (0x1 << 2)
-#define INT_POL (0x1 << 0)
+#define INT_POL1 (0x1 << 1)
+#define INT_POL0 (0x1 << 0)
/* EXYNOS_DP_SYS_CTL_1 */
#define DET_STA (0x1 << 2)