]> git.karo-electronics.de Git - linux-beck.git/commitdiff
drm/i915: Hack to tie both common lanes together on chv
authorVille Syrjälä <ville.syrjala@linux.intel.com>
Fri, 27 Jun 2014 16:49:57 +0000 (19:49 +0300)
committerDaniel Vetter <daniel.vetter@ffwll.ch>
Fri, 8 Aug 2014 15:43:56 +0000 (17:43 +0200)
It looks like frobbing the cmnreset line on pne PHY disturbs the other
PHY on chv. The result is a black screen. On HDMI it's just a flash of
black, but DP usually falls over and can't get back up.

As a workaround set up the power domains so that both common lane
wells power up and down together. I also tried leaving the cmnreset
deasserted even the if the power well goes down but that didn't seem
acceptable to the PHY.

Reviewed-by: Rafael Barbalho <rafael.barbalho@intel.com>
Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com>
Signed-off-by: Daniel Vetter <daniel.vetter@ffwll.ch>
drivers/gpu/drm/i915/intel_pm.c

index da43e30ad60b444addf1e565f6aa185458ff5ef9..aaae2281596594cdd514d919f12e11e8d4eeea45 100644 (file)
@@ -6877,13 +6877,23 @@ static struct i915_power_well chv_power_wells[] = {
 #endif
        {
                .name = "dpio-common-bc",
-               .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS,
+               /*
+                * XXX: cmnreset for one PHY seems to disturb the other.
+                * As a workaround keep both powered on at the same
+                * time for now.
+                */
+               .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS | CHV_DPIO_CMN_D_POWER_DOMAINS,
                .data = PUNIT_POWER_WELL_DPIO_CMN_BC,
                .ops = &chv_dpio_cmn_power_well_ops,
        },
        {
                .name = "dpio-common-d",
-               .domains = CHV_DPIO_CMN_D_POWER_DOMAINS,
+               /*
+                * XXX: cmnreset for one PHY seems to disturb the other.
+                * As a workaround keep both powered on at the same
+                * time for now.
+                */
+               .domains = CHV_DPIO_CMN_BC_POWER_DOMAINS | CHV_DPIO_CMN_D_POWER_DOMAINS,
                .data = PUNIT_POWER_WELL_DPIO_CMN_D,
                .ops = &chv_dpio_cmn_power_well_ops,
        },