Description:
This attribute is used to read the amount of quadrature error
present in the device at a given time.
-
-What: /sys/.../iio:deviceX/ac_excitation_en
-KernelVersion: 3.1.0
-Contact: linux-iio@vger.kernel.org
-Description:
- This attribute, if available, is used to enable the AC
- excitation mode found on some converters. In ac excitation mode,
- the polarity of the excitation voltage is reversed on
- alternate cycles, to eliminate DC errors.
-
-What: /sys/.../iio:deviceX/bridge_switch_en
-KernelVersion: 3.1.0
-Contact: linux-iio@vger.kernel.org
-Description:
- This attribute, if available, is used to close or open the
- bridge power down switch found on some converters.
- In bridge applications, such as strain gauges and load cells,
- the bridge itself consumes the majority of the current in the
- system. To minimize the current consumption of the system,
- the bridge can be disconnected (when it is not being used
- using the bridge_switch_en attribute.
--- /dev/null
+What: /sys/.../iio:deviceX/ac_excitation_en
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute, if available, is used to enable the AC
+ excitation mode found on some converters. In ac excitation mode,
+ the polarity of the excitation voltage is reversed on
+ alternate cycles, to eliminate DC errors.
+
+What: /sys/.../iio:deviceX/bridge_switch_en
+KernelVersion: 3.1.0
+Contact: linux-iio@vger.kernel.org
+Description:
+ This attribute, if available, is used to close or open the
+ bridge power down switch found on some converters.
+ In bridge applications, such as strain gauges and load cells,
+ the bridge itself consumes the majority of the current in the
+ system. To minimize the current consumption of the system,
+ the bridge can be disconnected (when it is not being used
+ using the bridge_switch_en attribute.