]> git.karo-electronics.de Git - linux-beck.git/commitdiff
HID: uclogic: Replace original rdescs with links
authorNikolai Kondrashov <spbnick@gmail.com>
Tue, 6 Mar 2012 07:54:22 +0000 (09:54 +0200)
committerJiri Kosina <jkosina@suse.cz>
Tue, 6 Mar 2012 10:20:54 +0000 (11:20 +0100)
Replace original report descriptor dumps in the comments with links to tablet
descriptions in a wiki, to make code clearer.

Signed-off-by: Nikolai Kondrashov <spbnick@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
drivers/hid/hid-uclogic.c

index e15732f1a22deb626116b9e0a6a24ca60cf62ee5..1f1128910337a5e004c60e4896c843d70b88b56c 100644 (file)
 #include "hid-ids.h"
 
 /*
- * The original descriptors of WPXXXXU tablets have three report IDs, of
- * which only two are used (8 and 9), and the remaining (7) seems to have
- * the originally intended pen description which was abandoned for some
- * reason.  From this unused description it is possible to extract the
- * actual physical extents and resolution. All the models use the same
- * descriptor with different extents for the unused report ID.
- *
- * Here it is:
- *
- *  Usage Page (Digitizer),         ; Digitizer (0Dh)
- *  Usage (Pen),                    ; Pen (02h, application collection)
- *  Collection (Application),
- *    Report ID (7),
- *    Usage (Stylus),               ; Stylus (20h, logical collection)
- *    Collection (Physical),
- *      Usage (Tip Switch),         ; Tip switch (42h, momentary control)
- *      Usage (Barrel Switch),      ; Barrel switch (44h, momentary control)
- *      Usage (Eraser),             ; Eraser (45h, momentary control)
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Size (1),
- *      Report Count (3),
- *      Input (Variable),
- *      Report Count (3),
- *      Input (Constant, Variable),
- *      Usage (In Range),           ; In range (32h, momentary control)
- *      Report Count (1),
- *      Input (Variable),
- *      Report Count (1),
- *      Input (Constant, Variable),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Report Size (16),
- *      Report Count (1),
- *      Push,
- *      Unit Exponent (13),
- *      Unit (Inch^3),
- *      Physical Minimum (0),
- *      Physical Maximum (Xpm),
- *      Logical Maximum (Xlm),
- *      Input (Variable),
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Physical Maximum (Ypm),
- *      Logical Maximum (Ylm),
- *      Input (Variable),
- *      Pop,
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Input (Variable),
- *      Report Size (16),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (8),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (5),
- *      Input (Constant),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Usage (Wheel),              ; Wheel (38h, dynamic value)
- *      Usage (00h),
- *      Logical Minimum (-127),
- *      Logical Maximum (127),
- *      Report Size (8),
- *      Report Count (4),
- *      Input (Variable, Relative),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (9),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (5),
- *      Input (Constant),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Logical Minimum (0),
- *      Logical Maximum (32767),
- *      Physical Minimum (0),
- *      Physical Maximum (32767),
- *      Report Count (2),
- *      Report Size (16),
- *      Input (Variable),
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Report Count (1),
- *      Report Size (16),
- *      Input (Variable),
- *    End Collection,
- *  End Collection
- *
- * Here are the extents values for the WPXXXXU models:
- *
- *              Xpm     Xlm     Ypm     Ylm
- *  WP4030U     4000    8000    3000    6000
- *  WP5540U     5500    11000   4000    8000
- *  WP8060U     8000    16000   6000    12000
- *
- * This suggests that all of them have 2000 LPI resolution, as advertised.
+ * See WPXXXXU model descriptions, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP4030U
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP5540U
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP8060U
  */
 
 /* Size of the original descriptor of WPXXXXU tablets */
 #define WPXXXXU_RDESC_ORIG_SIZE        212
 
-/*
- * Fixed WP4030U report descriptor.
- * Although the hardware might actually support it, the mouse description
- * has been removed, since there seems to be no devices having one and it
- * wouldn't make much sense because of the working area size.
- */
+/* Fixed WP4030U report descriptor */
 static __u8 wp4030u_rdesc_fixed[] = {
        0x05, 0x0D,         /*  Usage Page (Digitizer),             */
        0x09, 0x02,         /*  Usage (Pen),                        */
@@ -343,148 +218,14 @@ static __u8 wp8060u_rdesc_fixed[] = {
 };
 
 /*
- * Original WP1062 report descriptor.
- *
- * Only report ID 9 is actually used.
- *
- *  Usage Page (Digitizer),         ; Digitizer (0Dh)
- *  Usage (Pen),                    ; Pen (02h, application collection)
- *  Collection (Application),
- *    Report ID (7),
- *    Usage (Stylus),               ; Stylus (20h, logical collection)
- *    Collection (Physical),
- *      Usage (Tip Switch),         ; Tip switch (42h, momentary control)
- *      Usage (Barrel Switch),      ; Barrel switch (44h, momentary control)
- *      Usage (Eraser),             ; Eraser (45h, momentary control)
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Size (1),
- *      Report Count (3),
- *      Input (Variable),
- *      Report Count (3),
- *      Input (Constant, Variable),
- *      Usage (In Range),           ; In range (32h, momentary control)
- *      Report Count (1),
- *      Input (Variable),
- *      Report Count (1),
- *      Input (Constant, Variable),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Report Size (16),
- *      Report Count (1),
- *      Push,
- *      Unit Exponent (13),
- *      Unit (Inch),
- *      Physical Minimum (0),
- *      Physical Maximum (10000),
- *      Logical Maximum (20000),
- *      Input (Variable),
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Physical Maximum (6583),
- *      Logical Maximum (13166),
- *      Input (Variable),
- *      Pop,
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Input (Variable),
- *      Report Size (16),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (8),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (5),
- *      Input (Constant),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Usage (Wheel),              ; Wheel (38h, dynamic value)
- *      Usage (00h),
- *      Logical Minimum (-127),
- *      Logical Maximum (127),
- *      Report Size (8),
- *      Report Count (4),
- *      Input (Variable, Relative),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (9),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (4),
- *      Input (Constant),
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (In Range),           ; In range (32h, momentary control)
- *      Report Count (1),
- *      Input (Variable),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Report Size (16),
- *      Report Count (1),
- *      Push,
- *      Unit Exponent (13),
- *      Unit (Inch),
- *      Physical Minimum (0),
- *      Physical Maximum (10000),
- *      Logical Maximum (20000),
- *      Input (Variable),
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Physical Maximum (6583),
- *      Logical Maximum (13166),
- *      Input (Variable),
- *      Pop,
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Report Count (1),
- *      Report Size (16),
- *      Input (Variable),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (00h),
- *  Collection (Application),
- *    Report ID (4),
- *    Logical Minimum (0),
- *    Logical Maximum (255),
- *    Usage (00h),
- *    Report Size (8),
- *    Report Count (3),
- *    Feature (Variable),
- *  End Collection
+ * See WP1062 description, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP1062
  */
 
 /* Size of the original descriptor of WP1062 tablet */
 #define WP1062_RDESC_ORIG_SIZE 254
 
-/*
- * Fixed WP1062 report descriptor.
- *
- * Removed unused reports, corrected second barrel button usage code, physical
- * units.
- */
+/* Fixed WP1062 report descriptor */
 static __u8 wp1062_rdesc_fixed[] = {
        0x05, 0x0D,         /*  Usage Page (Digitizer),             */
        0x09, 0x02,         /*  Usage (Pen),                        */
@@ -530,146 +271,14 @@ static __u8 wp1062_rdesc_fixed[] = {
 };
 
 /*
- * Original PF1209 report descriptor.
- *
- * The descriptor is similar to WPXXXXU descriptors, with an addition of a
- * feature report (ID 4) of unknown purpose.
- *
- * Although the advertised resolution is 4000 LPI the unused report ID
- * (taken from WPXXXXU, it seems) states 2000 LPI, but it is probably
- * incorrect and is a result of blind copying without understanding. Anyway
- * the real logical extents are always scaled to 0..32767, which IMHO spoils
- * the precision.
- *
- *  Usage Page (Digitizer),         ; Digitizer (0Dh)
- *  Usage (Pen),                    ; Pen (02h, application collection)
- *  Collection (Application),
- *    Report ID (7),
- *    Usage (Stylus),               ; Stylus (20h, logical collection)
- *    Collection (Physical),
- *      Usage (Tip Switch),         ; Tip switch (42h, momentary control)
- *      Usage (Barrel Switch),      ; Barrel switch (44h, momentary control)
- *      Usage (Eraser),             ; Eraser (45h, momentary control)
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Size (1),
- *      Report Count (3),
- *      Input (Variable),
- *      Report Count (3),
- *      Input (Constant, Variable),
- *      Usage (In Range),           ; In range (32h, momentary control)
- *      Report Count (1),
- *      Input (Variable),
- *      Report Count (1),
- *      Input (Constant, Variable),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Report Size (16),
- *      Report Count (1),
- *      Push,
- *      Unit Exponent (13),
- *      Unit (Inch^3),
- *      Physical Minimum (0),
- *      Physical Maximum (12000),
- *      Logical Maximum (24000),
- *      Input (Variable),
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Physical Maximum (9000),
- *      Logical Maximum (18000),
- *      Input (Variable),
- *      Pop,
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Input (Variable),
- *      Report Size (16),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (8),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (5),
- *      Input (Constant),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Usage (Wheel),              ; Wheel (38h, dynamic value)
- *      Usage (00h),
- *      Logical Minimum (-127),
- *      Logical Maximum (127),
- *      Report Size (8),
- *      Report Count (4),
- *      Input (Variable, Relative),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (Mouse),                  ; Mouse (02h, application collection)
- *  Collection (Application),
- *    Report ID (9),
- *    Usage (Pointer),              ; Pointer (01h, physical collection)
- *    Collection (Physical),
- *      Usage Page (Button),        ; Button (09h)
- *      Usage Minimum (01h),
- *      Usage Maximum (03h),
- *      Logical Minimum (0),
- *      Logical Maximum (1),
- *      Report Count (3),
- *      Report Size (1),
- *      Input (Variable),
- *      Report Count (5),
- *      Input (Constant),
- *      Usage Page (Desktop),       ; Generic desktop controls (01h)
- *      Usage (X),                  ; X (30h, dynamic value)
- *      Usage (Y),                  ; Y (31h, dynamic value)
- *      Logical Minimum (0),
- *      Logical Maximum (32767),
- *      Physical Minimum (0),
- *      Physical Maximum (32767),
- *      Report Count (2),
- *      Report Size (16),
- *      Input (Variable),
- *      Usage Page (Digitizer),     ; Digitizer (0Dh)
- *      Usage (Tip Pressure),       ; Tip pressure (30h, dynamic value)
- *      Logical Maximum (1023),
- *      Report Count (1),
- *      Report Size (16),
- *      Input (Variable),
- *    End Collection,
- *  End Collection,
- *  Usage Page (Desktop),           ; Generic desktop controls (01h)
- *  Usage (00h),
- *  Collection (Application),
- *    Report ID (4),
- *    Logical Minimum (0),
- *    Logical Maximum (255),
- *    Usage (00h),
- *    Report Size (8),
- *    Report Count (3),
- *    Feature (Variable),
- *  End Collection
+ * See PF1209 description, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_PF1209
  */
 
 /* Size of the original descriptor of PF1209 tablet */
 #define PF1209_RDESC_ORIG_SIZE 234
 
-/*
- * Fixed PF1209 report descriptor
- *
- * The descriptor is fixed similarly to WP5540U and WP8060U, plus the
- * feature report is removed, because its purpose is unknown and it is of no
- * use to the generic HID driver anyway for now.
- */
+/* Fixed PF1209 report descriptor */
 static __u8 pf1209_rdesc_fixed[] = {
        0x05, 0x0D,         /*  Usage Page (Digitizer),             */
        0x09, 0x02,         /*  Usage (Pen),                        */