Since v2 hw only supports 2048 itct entries, as opposed to 4096 for v1
hw, set the max itct entries to the lower of the two.
It is not anticipated that any device with v1 will ever require to
connect > 2048 devices.
Signed-off-by: John Garry <john.garry@huawei.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
#define HISI_SAS_MAX_PHYS 9
#define HISI_SAS_MAX_QUEUES 32
#define HISI_SAS_QUEUE_SLOTS 512
-#define HISI_SAS_MAX_ITCT_ENTRIES 4096
+#define HISI_SAS_MAX_ITCT_ENTRIES 2048
#define HISI_SAS_MAX_DEVICES HISI_SAS_MAX_ITCT_ENTRIES