struct sched_domain *tmp, *sd = NULL;
for_each_domain(cpu, tmp) {
+ /*
+ * If power savings logic is enabled for a domain, stop there.
+ */
+ if (tmp->flags & SD_POWERSAVINGS_BALANCE)
+ break;
if (tmp->flags & flag)
sd = tmp;
}
unsigned long busiest_load_per_task, busiest_nr_running;
unsigned long this_load_per_task, this_nr_running;
int load_idx;
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+ int power_savings_balance = 1;
+ unsigned long leader_nr_running = 0, min_load_per_task = 0;
+ unsigned long min_nr_running = ULONG_MAX;
+ struct sched_group *group_min = NULL, *group_leader = NULL;
+#endif
max_load = this_load = total_load = total_pwr = 0;
busiest_load_per_task = busiest_nr_running = 0;
load_idx = sd->idle_idx;
do {
- unsigned long load;
+ unsigned long load, group_capacity;
int local_group;
int i;
unsigned long sum_nr_running, sum_weighted_load;
/* Adjust by relative CPU power of the group */
avg_load = (avg_load * SCHED_LOAD_SCALE) / group->cpu_power;
+ group_capacity = group->cpu_power / SCHED_LOAD_SCALE;
+
if (local_group) {
this_load = avg_load;
this = group;
this_nr_running = sum_nr_running;
this_load_per_task = sum_weighted_load;
} else if (avg_load > max_load &&
- sum_nr_running > group->cpu_power / SCHED_LOAD_SCALE) {
+ sum_nr_running > group_capacity) {
max_load = avg_load;
busiest = group;
busiest_nr_running = sum_nr_running;
busiest_load_per_task = sum_weighted_load;
}
+
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+ /*
+ * Busy processors will not participate in power savings
+ * balance.
+ */
+ if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+ goto group_next;
+
+ /*
+ * If the local group is idle or completely loaded
+ * no need to do power savings balance at this domain
+ */
+ if (local_group && (this_nr_running >= group_capacity ||
+ !this_nr_running))
+ power_savings_balance = 0;
+
+ /*
+ * If a group is already running at full capacity or idle,
+ * don't include that group in power savings calculations
+ */
+ if (!power_savings_balance || sum_nr_running >= group_capacity
+ || !sum_nr_running)
+ goto group_next;
+
+ /*
+ * Calculate the group which has the least non-idle load.
+ * This is the group from where we need to pick up the load
+ * for saving power
+ */
+ if ((sum_nr_running < min_nr_running) ||
+ (sum_nr_running == min_nr_running &&
+ first_cpu(group->cpumask) <
+ first_cpu(group_min->cpumask))) {
+ group_min = group;
+ min_nr_running = sum_nr_running;
+ min_load_per_task = sum_weighted_load /
+ sum_nr_running;
+ }
+
+ /*
+ * Calculate the group which is almost near its
+ * capacity but still has some space to pick up some load
+ * from other group and save more power
+ */
+ if (sum_nr_running <= group_capacity - 1)
+ if (sum_nr_running > leader_nr_running ||
+ (sum_nr_running == leader_nr_running &&
+ first_cpu(group->cpumask) >
+ first_cpu(group_leader->cpumask))) {
+ group_leader = group;
+ leader_nr_running = sum_nr_running;
+ }
+
+group_next:
+#endif
group = group->next;
} while (group != sd->groups);
return busiest;
out_balanced:
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+ if (idle == NOT_IDLE || !(sd->flags & SD_POWERSAVINGS_BALANCE))
+ goto ret;
+ if (this == group_leader && group_leader != group_min) {
+ *imbalance = min_load_per_task;
+ return group_min;
+ }
+ret:
+#endif
*imbalance = 0;
return NULL;
}
int active_balance = 0;
int sd_idle = 0;
- if (idle != NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER)
+ if (idle != NOT_IDLE && sd->flags & SD_SHARE_CPUPOWER &&
+ !sched_smt_power_savings)
sd_idle = 1;
schedstat_inc(sd, lb_cnt[idle]);
sd->balance_interval *= 2;
}
- if (!nr_moved && !sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+ if (!nr_moved && !sd_idle && sd->flags & SD_SHARE_CPUPOWER &&
+ !sched_smt_power_savings)
return -1;
return nr_moved;
(sd->balance_interval < sd->max_interval))
sd->balance_interval *= 2;
- if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+ if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
return -1;
return 0;
}
int nr_moved = 0;
int sd_idle = 0;
- if (sd->flags & SD_SHARE_CPUPOWER)
+ if (sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
sd_idle = 1;
schedstat_inc(sd, lb_cnt[NEWLY_IDLE]);
out_balanced:
schedstat_inc(sd, lb_balanced[NEWLY_IDLE]);
- if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER)
+ if (!sd_idle && sd->flags & SD_SHARE_CPUPOWER && !sched_smt_power_savings)
return -1;
sd->nr_balance_failed = 0;
return 0;
}
#endif
+int sched_smt_power_savings = 0, sched_mc_power_savings = 0;
/*
* At the moment, CONFIG_SCHED_SMT is never defined, but leave it in so we
* can switch it on easily if needed.
#endif
/* Calculate CPU power for physical packages and nodes */
+#ifdef CONFIG_SCHED_SMT
for_each_cpu_mask(i, *cpu_map) {
- int power;
struct sched_domain *sd;
-#ifdef CONFIG_SCHED_SMT
sd = &per_cpu(cpu_domains, i);
- power = SCHED_LOAD_SCALE;
- sd->groups->cpu_power = power;
+ sd->groups->cpu_power = SCHED_LOAD_SCALE;
+ }
#endif
#ifdef CONFIG_SCHED_MC
+ for_each_cpu_mask(i, *cpu_map) {
+ int power;
+ struct sched_domain *sd;
sd = &per_cpu(core_domains, i);
- power = SCHED_LOAD_SCALE + (cpus_weight(sd->groups->cpumask)-1)
+ if (sched_smt_power_savings)
+ power = SCHED_LOAD_SCALE * cpus_weight(sd->groups->cpumask);
+ else
+ power = SCHED_LOAD_SCALE + (cpus_weight(sd->groups->cpumask)-1)
* SCHED_LOAD_SCALE / 10;
sd->groups->cpu_power = power;
+ }
+#endif
+ for_each_cpu_mask(i, *cpu_map) {
+ struct sched_domain *sd;
+#ifdef CONFIG_SCHED_MC
sd = &per_cpu(phys_domains, i);
+ if (i != first_cpu(sd->groups->cpumask))
+ continue;
- /*
- * This has to be < 2 * SCHED_LOAD_SCALE
- * Lets keep it SCHED_LOAD_SCALE, so that
- * while calculating NUMA group's cpu_power
- * we can simply do
- * numa_group->cpu_power += phys_group->cpu_power;
- *
- * See "only add power once for each physical pkg"
- * comment below
- */
- sd->groups->cpu_power = SCHED_LOAD_SCALE;
+ sd->groups->cpu_power = 0;
+ if (sched_mc_power_savings || sched_smt_power_savings) {
+ int j;
+
+ for_each_cpu_mask(j, sd->groups->cpumask) {
+ struct sched_domain *sd1;
+ sd1 = &per_cpu(core_domains, j);
+ /*
+ * for each core we will add once
+ * to the group in physical domain
+ */
+ if (j != first_cpu(sd1->groups->cpumask))
+ continue;
+
+ if (sched_smt_power_savings)
+ sd->groups->cpu_power += sd1->groups->cpu_power;
+ else
+ sd->groups->cpu_power += SCHED_LOAD_SCALE;
+ }
+ } else
+ /*
+ * This has to be < 2 * SCHED_LOAD_SCALE
+ * Lets keep it SCHED_LOAD_SCALE, so that
+ * while calculating NUMA group's cpu_power
+ * we can simply do
+ * numa_group->cpu_power += phys_group->cpu_power;
+ *
+ * See "only add power once for each physical pkg"
+ * comment below
+ */
+ sd->groups->cpu_power = SCHED_LOAD_SCALE;
#else
+ int power;
sd = &per_cpu(phys_domains, i);
- power = SCHED_LOAD_SCALE + SCHED_LOAD_SCALE *
- (cpus_weight(sd->groups->cpumask)-1) / 10;
+ if (sched_smt_power_savings)
+ power = SCHED_LOAD_SCALE * cpus_weight(sd->groups->cpumask);
+ else
+ power = SCHED_LOAD_SCALE;
sd->groups->cpu_power = power;
#endif
}
return err;
}
+#if defined(CONFIG_SCHED_MC) || defined(CONFIG_SCHED_SMT)
+int arch_reinit_sched_domains(void)
+{
+ int err;
+
+ lock_cpu_hotplug();
+ detach_destroy_domains(&cpu_online_map);
+ err = arch_init_sched_domains(&cpu_online_map);
+ unlock_cpu_hotplug();
+
+ return err;
+}
+
+static ssize_t sched_power_savings_store(const char *buf, size_t count, int smt)
+{
+ int ret;
+
+ if (buf[0] != '0' && buf[0] != '1')
+ return -EINVAL;
+
+ if (smt)
+ sched_smt_power_savings = (buf[0] == '1');
+ else
+ sched_mc_power_savings = (buf[0] == '1');
+
+ ret = arch_reinit_sched_domains();
+
+ return ret ? ret : count;
+}
+
+int sched_create_sysfs_power_savings_entries(struct sysdev_class *cls)
+{
+ int err = 0;
+#ifdef CONFIG_SCHED_SMT
+ if (smt_capable())
+ err = sysfs_create_file(&cls->kset.kobj,
+ &attr_sched_smt_power_savings.attr);
+#endif
+#ifdef CONFIG_SCHED_MC
+ if (!err && mc_capable())
+ err = sysfs_create_file(&cls->kset.kobj,
+ &attr_sched_mc_power_savings.attr);
+#endif
+ return err;
+}
+#endif
+
+#ifdef CONFIG_SCHED_MC
+static ssize_t sched_mc_power_savings_show(struct sys_device *dev, char *page)
+{
+ return sprintf(page, "%u\n", sched_mc_power_savings);
+}
+static ssize_t sched_mc_power_savings_store(struct sys_device *dev, const char *buf, size_t count)
+{
+ return sched_power_savings_store(buf, count, 0);
+}
+SYSDEV_ATTR(sched_mc_power_savings, 0644, sched_mc_power_savings_show,
+ sched_mc_power_savings_store);
+#endif
+
+#ifdef CONFIG_SCHED_SMT
+static ssize_t sched_smt_power_savings_show(struct sys_device *dev, char *page)
+{
+ return sprintf(page, "%u\n", sched_smt_power_savings);
+}
+static ssize_t sched_smt_power_savings_store(struct sys_device *dev, const char *buf, size_t count)
+{
+ return sched_power_savings_store(buf, count, 1);
+}
+SYSDEV_ATTR(sched_smt_power_savings, 0644, sched_smt_power_savings_show,
+ sched_smt_power_savings_store);
+#endif
+
+
#ifdef CONFIG_HOTPLUG_CPU
/*
* Force a reinitialization of the sched domains hierarchy. The domains