Connecting two boards directly more than 2 hours, Ar8031 phy link
status generates glitch, which cause ethernet link down/up issue, but
ethernet still be active. There have three cases to validate the issue:
Item#1: If add performance stress test while runing IEEE1588, the link
down/up issue cannot be found.
Item#2: If insert switch between two net nodes and run IEEE1588 test,
the issue also cannot be found.
Item#3: If disable AR8031 SmartEEE feature, after two days overnight test,
no such issue found.
The issue is caused by phy Ar8031 SmartEEE feature, Item#1 and Item#2 can
prevent phy enter lpm mode, which match the Item#3 test result, so disable
SmartEEE feature to avoid the link issue generation.
Signed-off-by: Luwei Zhou <B45643@freescale.com>
{
u16 val;
+ /* disable phy AR8031 SmartEEE function. */
+ phy_write(dev, 0xd, 0x3);
+ phy_write(dev, 0xe, 0x805d);
+ phy_write(dev, 0xd, 0x4003);
+ val = phy_read(dev, 0xe);
+ val &= ~(0x1 << 8);
+ phy_write(dev, 0xe, val);
+
/* To enable AR8031 output a 125MHz clk from CLK_25M */
phy_write(dev, 0xd, 0x7);
phy_write(dev, 0xe, 0x8016);