Datasheet says (Page 2) that typical value for sensitivity
for 16 bits mode on Z-axis is 770. Anyhow, looking at the
input driver provided by Memsic the value for MMC35240 is
1024.
Also, testing shows that using 1024 for Z-axis senzitivity
offers better results.
Fixes: abeb6b1e7b ("iio: magnetometer: Add support for MEMSIC MMC35240")
Signed-off-by: Daniel Baluta <daniel.baluta@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
} mmc35240_props_table[] = {
/* 16 bits, 100Hz ODR */
{
- {1024, 1024, 770},
+ {1024, 1024, 1024},
32768,
},
/* 16 bits, 200Hz ODR */