Adding UART_CAP_EFR and UART_CAP_SLEEP flags will enable sleep mode
and automatic CTS flow control for 16C950 UARTs. It will also avoid
capabilities detection warning like this:
"ttyS0: detected caps
00000700 should be
00000100"
Signed-off-by: Yegor Yefremov <yegorslists@googlemail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
.fifo_size = 128,
.tx_loadsz = 128,
.fcr = UART_FCR_ENABLE_FIFO | UART_FCR_R_TRIG_10,
- .flags = UART_CAP_FIFO,
+ .flags = UART_CAP_FIFO | UART_CAP_EFR | UART_CAP_SLEEP,
},
[PORT_16654] = {
.name = "ST16654",