Broadcom ARM devices seem to generate some fault once per boot. We
already have an ignoring handler for BCM4707/BCM4708, but BCM4709
generates different code.
Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
static int bcm5301x_abort_handler(unsigned long addr, unsigned int fsr,
struct pt_regs *regs)
{
- if (fsr == 0x1c06 && first_fault) {
+ if ((fsr == 0x1406 || fsr == 0x1c06) && first_fault) {
first_fault = false;
/*
- * These faults with code 0x1c06 happens for no good reason,
- * possibly left over from the CFE boot loader.
+ * These faults with codes 0x1406 (BCM4709) or 0x1c06 happens
+ * for no good reason, possibly left over from the CFE boot
+ * loader.
*/
pr_warn("External imprecise Data abort at addr=%#lx, fsr=%#x ignored.\n",
- addr, fsr);
+ addr, fsr);
/* Returning non-zero causes fault display and panic */
return 0;