To get correct calibration, we can decrease the time
needed for the OSC to calibrate itself.
With this change we can save ~15ms in the OSC
calibration phase.
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
/* Write registers 0x08 and 0x09 (MSB, LSB) */
dac33_write16(codec, DAC33_INT_OSC_FREQ_RAT_A, oscset);
- /* calib time: 128 is a nice number ;) */
- dac33_write(codec, DAC33_CALIB_TIME, 128);
+ /* OSC calibration time */
+ dac33_write(codec, DAC33_CALIB_TIME, 96);
/* adjustment treshold & step */
dac33_write(codec, DAC33_INT_OSC_CTRL_B, DAC33_ADJTHRSHLD(2) |