Currently MIN_LATENCY_MULTIPLIER is set defined as 100 and so on a system with
transition latency of 1 ms, the minimum sampling time comes to be around 100 ms.
That is quite big if you want to get better performance for your system.
Redefine MIN_LATENCY_MULTIPLIER to 20 so that we can support 20ms sampling rate
for such platforms.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
*/
#define MIN_SAMPLING_RATE_RATIO (2)
#define LATENCY_MULTIPLIER (1000)
-#define MIN_LATENCY_MULTIPLIER (100)
+#define MIN_LATENCY_MULTIPLIER (20)
#define TRANSITION_LATENCY_LIMIT (10 * 1000 * 1000)
/* Ondemand Sampling types */