The battery_charging and cable_state flags were backwards on the Sixaxis.
The low bit of report byte 30 is 0 when charging and 1 when not.
Bit 5 of byte 31 is 0 when a USB cable is connected and 1 when not.
Signed-off-by: Frank Praznik <frank.praznik@oh.rr.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
*/
if (rd[30] >= 0xee) {
battery_capacity = 100;
- battery_charging = rd[30] & 0x01;
+ battery_charging = !(rd[30] & 0x01);
} else {
battery_capacity = sixaxis_battery_capacity[rd[30]];
battery_charging = 0;
}
- cable_state = (rd[31] >> 4) & 0x01;
+ cable_state = !((rd[31] >> 4) & 0x01);
spin_lock_irqsave(&sc->lock, flags);
sc->cable_state = cable_state;