Temperature reads on bmp280 device always return 0,
due to a missing step in the compensation formula
(data->tfine is never initialized).
Initialize data->tfine value so we get correct
temperature and pressure values.
Signed-off-by: Irina Tirdea <irina.tirdea@intel.com>
Reviewed-by: Vlad Dogaru <vlad.dogaru@intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
var2 = (((((adc_temp >> 4) - ((s32)le16_to_cpu(buf[T1]))) *
((adc_temp >> 4) - ((s32)le16_to_cpu(buf[T1])))) >> 12) *
((s32)(s16)le16_to_cpu(buf[T3]))) >> 14;
+ data->t_fine = var1 + var2;
return (data->t_fine * 5 + 128) >> 8;
}