commit
9716387311c790de381214c03e7f1b72b91a8189 upstream.
According to the HT6560H datasheet, the recovery timing field is 4-bit wide,
with a value of 0 meaning 16 cycles. Correct obvious thinko in the recovery
field mask.
Signed-off-by: Sergei Shtylyov <sshtylyov@ru.mvista.com>
Signed-off-by: Jeff Garzik <jgarzik@redhat.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
ata_timing_compute(adev, adev->pio_mode, &t, 20000, 1000);
active = clamp_val(t.active, 2, 15);
- recover = clamp_val(t.recover, 2, 16);
- recover &= 0x15;
+ recover = clamp_val(t.recover, 2, 16) & 0x0F;
inb(0x3E6);
inb(0x3E6);