return abreg->typ_voltages[regval];
}
-static int ab3100_get_best_voltage_index(struct regulator_dev *reg,
- int min_uV, int max_uV)
-{
- struct ab3100_regulator *abreg = reg->reg_data;
- int i;
- int bestmatch;
- int bestindex;
-
- /*
- * Locate the minimum voltage fitting the criteria on
- * this regulator. The switchable voltages are not
- * in strict falling order so we need to check them
- * all for the best match.
- */
- bestmatch = INT_MAX;
- bestindex = -1;
- for (i = 0; i < abreg->voltages_len; i++) {
- if (abreg->typ_voltages[i] <= max_uV &&
- abreg->typ_voltages[i] >= min_uV &&
- abreg->typ_voltages[i] < bestmatch) {
- bestmatch = abreg->typ_voltages[i];
- bestindex = i;
- }
- }
-
- if (bestindex < 0) {
- dev_warn(®->dev, "requested %d<=x<=%d uV, out of range!\n",
- min_uV, max_uV);
- return -EINVAL;
- }
- return bestindex;
-}
-
static int ab3100_set_voltage_regulator_sel(struct regulator_dev *reg,
unsigned selector)
{
return -EINVAL;
/* LDO E and BUCK have special suspend voltages you can set */
- bestindex = ab3100_get_best_voltage_index(reg, uV, uV);
+ bestindex = regulator_map_voltage_iterate(reg, uV, uV);
err = abx500_get_register_interruptible(abreg->dev, 0,
targetreg, ®val);