]> git.karo-electronics.de Git - linux-beck.git/commitdiff
Bluetooth: Fix buffer overflow with variable length commands
authorJohan Hedberg <johan.hedberg@intel.com>
Thu, 3 Jul 2014 10:52:27 +0000 (13:52 +0300)
committerMarcel Holtmann <marcel@holtmann.org>
Thu, 3 Jul 2014 15:42:59 +0000 (17:42 +0200)
The handler for variable length commands were trying to calculate the
expected length of the command based on the given parameter count, and
then comparing that with the received data. However, the expected count
was stored in a u16 which can easily overflow. With a carefully crafted
command this can then be made to match the given data even though the
parameter count is actually way too big, resulting in a buffer overflow
when parsing the parameters.

This patch fixes the issue by calculating a per-command maximum
parameter count and returns INVALID_PARAMS if it is exceeded.

Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
Signed-off-by: Marcel Holtmann <marcel@holtmann.org>
net/bluetooth/mgmt.c

index 0a82f08cd191e1059b5b2b6f9845dbdc7e46de08..c01cc5e37a6f062b856f7d5d67945ee06c77abc1 100644 (file)
@@ -2468,6 +2468,8 @@ static int load_link_keys(struct sock *sk, struct hci_dev *hdev, void *data,
                          u16 len)
 {
        struct mgmt_cp_load_link_keys *cp = data;
+       const u16 max_key_count = ((U16_MAX - sizeof(*cp)) /
+                                  sizeof(struct mgmt_link_key_info));
        u16 key_count, expected_len;
        bool changed;
        int i;
@@ -2479,6 +2481,12 @@ static int load_link_keys(struct sock *sk, struct hci_dev *hdev, void *data,
                                  MGMT_STATUS_NOT_SUPPORTED);
 
        key_count = __le16_to_cpu(cp->key_count);
+       if (key_count > max_key_count) {
+               BT_ERR("load_link_keys: too big key_count value %u",
+                      key_count);
+               return cmd_status(sk, hdev->id, MGMT_OP_LOAD_LINK_KEYS,
+                                 MGMT_STATUS_INVALID_PARAMS);
+       }
 
        expected_len = sizeof(*cp) + key_count *
                                        sizeof(struct mgmt_link_key_info);
@@ -4568,6 +4576,8 @@ static int load_irks(struct sock *sk, struct hci_dev *hdev, void *cp_data,
                     u16 len)
 {
        struct mgmt_cp_load_irks *cp = cp_data;
+       const u16 max_irk_count = ((U16_MAX - sizeof(*cp)) /
+                                  sizeof(struct mgmt_irk_info));
        u16 irk_count, expected_len;
        int i, err;
 
@@ -4578,6 +4588,11 @@ static int load_irks(struct sock *sk, struct hci_dev *hdev, void *cp_data,
                                  MGMT_STATUS_NOT_SUPPORTED);
 
        irk_count = __le16_to_cpu(cp->irk_count);
+       if (irk_count > max_irk_count) {
+               BT_ERR("load_irks: too big irk_count value %u", irk_count);
+               return cmd_status(sk, hdev->id, MGMT_OP_LOAD_IRKS,
+                                 MGMT_STATUS_INVALID_PARAMS);
+       }
 
        expected_len = sizeof(*cp) + irk_count * sizeof(struct mgmt_irk_info);
        if (expected_len != len) {
@@ -4647,6 +4662,8 @@ static int load_long_term_keys(struct sock *sk, struct hci_dev *hdev,
                               void *cp_data, u16 len)
 {
        struct mgmt_cp_load_long_term_keys *cp = cp_data;
+       const u16 max_key_count = ((U16_MAX - sizeof(*cp)) /
+                                  sizeof(struct mgmt_ltk_info));
        u16 key_count, expected_len;
        int i, err;
 
@@ -4657,6 +4674,11 @@ static int load_long_term_keys(struct sock *sk, struct hci_dev *hdev,
                                  MGMT_STATUS_NOT_SUPPORTED);
 
        key_count = __le16_to_cpu(cp->key_count);
+       if (key_count > max_key_count) {
+               BT_ERR("load_ltks: too big key_count value %u", key_count);
+               return cmd_status(sk, hdev->id, MGMT_OP_LOAD_LONG_TERM_KEYS,
+                                 MGMT_STATUS_INVALID_PARAMS);
+       }
 
        expected_len = sizeof(*cp) + key_count *
                                        sizeof(struct mgmt_ltk_info);
@@ -5204,6 +5226,8 @@ static int load_conn_param(struct sock *sk, struct hci_dev *hdev, void *data,
                           u16 len)
 {
        struct mgmt_cp_load_conn_param *cp = data;
+       const u16 max_param_count = ((U16_MAX - sizeof(*cp)) /
+                                    sizeof(struct mgmt_conn_param));
        u16 param_count, expected_len;
        int i;
 
@@ -5212,6 +5236,12 @@ static int load_conn_param(struct sock *sk, struct hci_dev *hdev, void *data,
                                  MGMT_STATUS_NOT_SUPPORTED);
 
        param_count = __le16_to_cpu(cp->param_count);
+       if (param_count > max_param_count) {
+               BT_ERR("load_conn_param: too big param_count value %u",
+                      param_count);
+               return cmd_status(sk, hdev->id, MGMT_OP_LOAD_CONN_PARAM,
+                                 MGMT_STATUS_INVALID_PARAMS);
+       }
 
        expected_len = sizeof(*cp) + param_count *
                                        sizeof(struct mgmt_conn_param);