Currently autoidle is only enabled for OMAP2/3; by enabling autoidle,
the automatic L4 clock gating strategy is applied based on L4 activity,
otherwise L4 clock to module will be a free running.
Signed-off-by: Ambresh K <ambresh@ti.com>
[tony@atomide.com: updated for timer init changes]
Signed-off-by: Tony Lindgren <tony@atomide.com>
}
omap_dm_timer_set_source(timer, OMAP_TIMER_SRC_32_KHZ);
- /* Enable autoidle on OMAP2 / OMAP3 */
- if (cpu_is_omap24xx() || cpu_is_omap34xx())
+ /* Enable autoidle on OMAP2+ */
+ if (cpu_class_is_omap2())
autoidle = 1;
/*