If a load or store is the last instruction in a zero-overhead-loop, and
it's misaligned, the loop would execute only once.
This fixes that problem.
Signed-off-by: Mischa Jonker <mjonker@synopsys.com>
Signed-off-by: Vineet Gupta <vgupta@synopsys.com>
regs->status32 &= ~STATUS_DE_MASK;
} else {
regs->ret += state.instr_len;
+
+ /* handle zero-overhead-loop */
+ if ((regs->ret == regs->lp_end) && (regs->lp_count)) {
+ regs->ret = regs->lp_start;
+ regs->lp_count--;
+ }
}
return 0;