if (pdn->eeh_pe_config_addr)
config_addr = pdn->eeh_pe_config_addr;
- rc = rtas_call(ibm_set_slot_reset,4,1, NULL,
+ rc = rtas_call(ibm_set_slot_reset, 4, 1, NULL,
config_addr,
BUID_HI(pdn->phb->buid),
BUID_LO(pdn->phb->buid),
state);
- if (rc)
- printk (KERN_WARNING "EEH: Unable to reset the failed slot,"
- " (%d) #RST=%d dn=%s\n",
- rc, state, pdn->node->full_name);
+
+ /* Fundamental-reset not supported on this PE, try hot-reset */
+ if (rc == -8 && state == 3) {
+ rc = rtas_call(ibm_set_slot_reset, 4, 1, NULL,
+ config_addr,
+ BUID_HI(pdn->phb->buid),
+ BUID_LO(pdn->phb->buid), 1);
+ if (rc)
+ printk(KERN_WARNING
+ "EEH: Unable to reset the failed slot,"
+ " #RST=%d dn=%s\n",
+ rc, pdn->node->full_name);
+ }
}
/**