* Convert to unit value in mA
- * Full scale input voltage is
- * 66.660mV => LSB = 66.660mV/(4096*res) = 1.627mA
- * Given a 250ms conversion cycle time the LSB corresponds
- * to 112.9 nAh. Convert to current by dividing by the conversion
+ * by dividing by the conversion
* time in hours (= samples / (3600 * 4)h)
- * 112.9nAh assumes 10mOhm, but fg_res is in 0.1mOhm
+ * and multiply with 1000
*/
di->avg_curr = (val * QLSB_NANO_AMP_HOURS_X10 * 36) /
(1000 * di->bm->fg_res * (di->fg_samples / 4));
queue_work(di->fg_wq, &di->fg_work);
+ dev_dbg(di->dev, "fg_res: %d, fg_samples: %d, gasg: %d, accu_charge: %d \n",
+ di->bm->fg_res, di->fg_samples, val, di->accu_charge);
return;
exit:
dev_err(di->dev,