From: Ondrej Zary Date: Wed, 11 Feb 2009 21:08:43 +0000 (-0800) Subject: pata_it821x: resume from hibernation fails with RAID volume X-Git-Url: https://git.karo-electronics.de/?a=commitdiff_plain;h=7ba07d16bd62f931efec1fc8e63bf1aeebfe42a9;p=linux-beck.git pata_it821x: resume from hibernation fails with RAID volume Hibernation didn't work for me since I started to use IT8212 controller. I did some debugging (booting with no_console_suspend init=/bin/sh). Found that resume fails (2.6.28) with "serial number mismatch 'some garbage' != 'some other garbage'" and "revalidation failed" messages. That's because the controller firmware fills different serial number in the IDENTIFY every boot. The patch below fixes the resume simply clearing the serial number. The proper fix would be probably to fill in the serial number of the RAID volume instead. I assume that there must be something like that stored on the drives but I don't know where. Fix resume on pata_it821x RAID volume by clearing the serial number in IDENTIFY data, which is otherwise different on each boot. Signed-off-by: Ondrej Zary Acked-by: Alan Cox Signed-off-by: Andrew Morton Signed-off-by: Jeff Garzik --- diff --git a/drivers/ata/pata_it821x.c b/drivers/ata/pata_it821x.c index f1bb2f9fecbf..b05b86a912c5 100644 --- a/drivers/ata/pata_it821x.c +++ b/drivers/ata/pata_it821x.c @@ -557,6 +557,9 @@ static unsigned int it821x_read_id(struct ata_device *adev, id[83] |= 0x4400; /* Word 83 is valid and LBA48 */ id[86] |= 0x0400; /* LBA48 on */ id[ATA_ID_MAJOR_VER] |= 0x1F; + /* Clear the serial number because it's different each boot + which breaks validation on resume */ + memset(&id[ATA_ID_SERNO], 0x20, ATA_ID_SERNO_LEN); } return err_mask; }