From: Vojtech Pavlik Date: Mon, 26 Jun 2006 11:58:35 +0000 (+0200) Subject: [PATCH] x86_64: Explain why HPET T0_CMP register is written twice X-Git-Url: https://git.karo-electronics.de/?a=commitdiff_plain;h=b2df3ddb68fc02e3bae78b7adaeca8561d02ea6d;p=linux-beck.git [PATCH] x86_64: Explain why HPET T0_CMP register is written twice After writing the CFG register, the first value written to the T0_CMP register is the value at which next interrupt should be triggered, every value after that sets the period of the interrupt. For that reason, the code needs to write the value twice - to set both the phase and period. [AK: I had already figured it out by myself, but it's still useful to have a comment for this.] Signed-off-by: Vojtech Pavlik Signed-off-by: Andi Kleen Signed-off-by: Linus Torvalds --- diff --git a/arch/x86_64/kernel/time.c b/arch/x86_64/kernel/time.c index 51afb07bc14e..ee622ac0376b 100644 --- a/arch/x86_64/kernel/time.c +++ b/arch/x86_64/kernel/time.c @@ -795,8 +795,8 @@ static int hpet_timer_stop_set_go(unsigned long tick) if (hpet_use_timer) { hpet_writel(HPET_TN_ENABLE | HPET_TN_PERIODIC | HPET_TN_SETVAL | HPET_TN_32BIT, HPET_T0_CFG); - hpet_writel(hpet_tick, HPET_T0_CMP); - hpet_writel(hpet_tick, HPET_T0_CMP); /* AK: why twice? */ + hpet_writel(hpet_tick, HPET_T0_CMP); /* next interrupt */ + hpet_writel(hpet_tick, HPET_T0_CMP); /* period */ cfg |= HPET_CFG_LEGACY; } /*