From: Philipp Zabel
Date: Wed, 12 Aug 2015 10:32:13 +0000 (+0200)
Subject: drm/panel: simple: Correct minimum hsync length of the HannStar HSD070PWW1 panel
X-Git-Url: https://git.karo-electronics.de/?a=commitdiff_plain;h=d901d2ba8a1577ea213e4c4e22e9ca1f67db61dd;p=linux-beck.git
drm/panel: simple: Correct minimum hsync length of the HannStar HSD070PWW1 panel
According to the data sheet, the minimum horizontal blanking interval
is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
minimum working horizontal blanking interval to be 60 clocks.
Signed-off-by: Philipp Zabel
Signed-off-by: Lucas Stach
Signed-off-by: Thierry Reding
---
diff --git a/drivers/gpu/drm/panel/panel-simple.c b/drivers/gpu/drm/panel/panel-simple.c
index a1cd431e17a6..39e9dffe07d9 100644
--- a/drivers/gpu/drm/panel/panel-simple.c
+++ b/drivers/gpu/drm/panel/panel-simple.c
@@ -713,7 +713,12 @@ static const struct display_timing hannstar_hsd070pww1_timing = {
.hactive = { 1280, 1280, 1280 },
.hfront_porch = { 1, 1, 10 },
.hback_porch = { 1, 1, 10 },
- .hsync_len = { 52, 158, 661 },
+ /*
+ * According to the data sheet, the minimum horizontal blanking interval
+ * is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the
+ * minimum working horizontal blanking interval to be 60 clocks.
+ */
+ .hsync_len = { 58, 158, 661 },
.vactive = { 800, 800, 800 },
.vfront_porch = { 1, 1, 10 },
.vback_porch = { 1, 1, 10 },