From: Erik Arfvidson Date: Mon, 8 Feb 2016 15:41:46 +0000 (-0500) Subject: staging: unisys: fix comparison to NULL in visorchipset.c X-Git-Url: https://git.karo-electronics.de/?a=commitdiff_plain;h=e4a3dd33e5756f89c997099983e27f01727b0a37;p=linux-beck.git staging: unisys: fix comparison to NULL in visorchipset.c This patch fixes the following type of check patch warnings: Comparison to NULL could be written Signed-off-by: Erik Arfvidson Signed-off-by: Benjamin Romer Signed-off-by: Greg Kroah-Hartman --- diff --git a/drivers/staging/unisys/visorbus/visorchipset.c b/drivers/staging/unisys/visorbus/visorchipset.c index 085d19a56866..ab8f9ddc6424 100644 --- a/drivers/staging/unisys/visorbus/visorchipset.c +++ b/drivers/staging/unisys/visorbus/visorchipset.c @@ -438,7 +438,7 @@ parser_id_get(struct parser_context *ctx) { struct spar_controlvm_parameters_header *phdr = NULL; - if (ctx == NULL) + if (!ctx) return NULL_UUID_LE; phdr = (struct spar_controlvm_parameters_header *)(ctx->data); return phdr->id; @@ -461,7 +461,7 @@ parser_param_start(struct parser_context *ctx, { struct spar_controlvm_parameters_header *phdr = NULL; - if (ctx == NULL) + if (!ctx) goto Away; phdr = (struct spar_controlvm_parameters_header *)(ctx->data); switch (which_string) { @@ -522,7 +522,7 @@ parser_string_get(struct parser_context *ctx) if (value_length < 0) /* '\0' was not included in the length */ value_length = nscan; value = kmalloc(value_length + 1, GFP_KERNEL | __GFP_NORETRY); - if (value == NULL) + if (!value) return NULL; if (value_length > 0) memcpy(value, pscan, value_length); @@ -875,7 +875,7 @@ bus_responder(enum controlvm_id cmd_id, struct controlvm_message_header *pending_msg_hdr, int response) { - if (pending_msg_hdr == NULL) + if (!pending_msg_hdr) return; /* no controlvm response needed */ if (pending_msg_hdr->id != (u32)cmd_id) @@ -893,7 +893,7 @@ device_changestate_responder(enum controlvm_id cmd_id, u32 bus_no = p->chipset_bus_no; u32 dev_no = p->chipset_dev_no; - if (p->pending_msg_hdr == NULL) + if (!p->pending_msg_hdr) return; /* no controlvm response needed */ if (p->pending_msg_hdr->id != cmd_id) return; @@ -914,7 +914,7 @@ device_responder(enum controlvm_id cmd_id, struct controlvm_message_header *pending_msg_hdr, int response) { - if (pending_msg_hdr == NULL) + if (!pending_msg_hdr) return; /* no controlvm response needed */ if (pending_msg_hdr->id != (u32)cmd_id) @@ -1180,7 +1180,7 @@ bus_configure(struct controlvm_message *inmsg, POSTCODE_LINUX_3(BUS_CONFIGURE_FAILURE_PC, bus_no, POSTCODE_SEVERITY_ERR); rc = -CONTROLVM_RESP_ERROR_BUS_INVALID; - } else if (bus_info->pending_msg_hdr != NULL) { + } else if (bus_info->pending_msg_hdr) { POSTCODE_LINUX_3(BUS_CONFIGURE_FAILURE_PC, bus_no, POSTCODE_SEVERITY_ERR); rc = -CONTROLVM_RESP_ERROR_MESSAGE_ID_INVALID_FOR_CLIENT;