From 38a1981ce31dc4c527cbc0137f638543261b471a Mon Sep 17 00:00:00 2001 From: Sricharan R Date: Wed, 18 Sep 2013 16:50:11 +0530 Subject: [PATCH] ARM: OMAP2+: DRA7: realtime_counter: Add ratio registers for 20MHZ sys-clk frequency The real time counter also called master counter, is a free-running counter. It produces the count used by the CPU local timer peripherals in the MPU cluster. The timer counts at a rate of 6.144 MHz. The ratio registers are missing for a sys-clk of 20MHZ which is used by DRA7 socs. So because of this, the counter was getting wrongly programmed for a sys-clk of 38.4Mhz(default). So adding the ratio registers for 20MHZ sys-clk. Tested-by: Nishanth Menon Acked-by: Santosh Shilimkar Signed-off-by: Sricharan R Signed-off-by: Tony Lindgren --- arch/arm/mach-omap2/timer.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/arch/arm/mach-omap2/timer.c b/arch/arm/mach-omap2/timer.c index fa74a0625da1..d0f80c020423 100644 --- a/arch/arm/mach-omap2/timer.c +++ b/arch/arm/mach-omap2/timer.c @@ -515,6 +515,10 @@ static void __init realtime_counter_init(void) num = 8; den = 25; break; + case 20000000: + num = 192; + den = 625; + break; case 2600000: num = 384; den = 1625; -- 2.39.5