From ae3e101286df40cdde49c4737e2868289ed7f35b Mon Sep 17 00:00:00 2001 From: Axel Lin Date: Thu, 12 Sep 2013 09:38:12 +0800 Subject: [PATCH] regulator: palmas: Remove wrong comment for the equation calculating num_voltages Current equation on the comment is wrong. For linear mapping starting from 0, the equation is (maxV-minV)/stepV + 1. Since the linear mapping for PALMAS is not all starting from 0, the equation on the comment is not useful and misleading. Thus remove it. Signed-off-by: Axel Lin Signed-off-by: Mark Brown --- drivers/regulator/palmas-regulator.c | 6 ------ 1 file changed, 6 deletions(-) diff --git a/drivers/regulator/palmas-regulator.c b/drivers/regulator/palmas-regulator.c index fba4faa422b8..7e2b165972e6 100644 --- a/drivers/regulator/palmas-regulator.c +++ b/drivers/regulator/palmas-regulator.c @@ -201,12 +201,6 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500}; #define SMPS_CTRL_MODE_ECO 0x02 #define SMPS_CTRL_MODE_PWM 0x03 -/* These values are derived from the data sheet. And are the number of steps - * where there is a voltage change, the ranges at beginning and end of register - * max/min values where there are no change are ommitted. - * - * So they are basically (maxV-minV)/stepV - */ #define PALMAS_SMPS_NUM_VOLTAGES 122 #define PALMAS_SMPS10_NUM_VOLTAGES 2 #define PALMAS_LDO_NUM_VOLTAGES 50 -- 2.39.5