From ced2284339580b50b997807d02ccee19692b72b3 Mon Sep 17 00:00:00 2001 From: "lan,Tianyu" Date: Thu, 3 Apr 2014 14:04:15 +0800 Subject: [PATCH] Thermal/int3403: Fix thermal hysteresis unit conversion Thermal hysteresis represents a temperature difference. But the original code treats it as a temperature value, Convert it from tenths of degree Kelvin to Milli-Celsius by deducing 273200. This is not right. Kelvin and Celsius have same degree size. From temperature difference view, the conversion between tenths of degree Kelvin unit and Milli-Celsius unit is just to multiply 100. Signed-off-by: Lan Tianyu Acked-by: Srinivas Pandruvada Signed-off-by: Zhang Rui --- drivers/thermal/int3403_thermal.c | 8 +++++++- 1 file changed, 7 insertions(+), 1 deletion(-) diff --git a/drivers/thermal/int3403_thermal.c b/drivers/thermal/int3403_thermal.c index 1301681d9a77..e93f0253f6ed 100644 --- a/drivers/thermal/int3403_thermal.c +++ b/drivers/thermal/int3403_thermal.c @@ -62,7 +62,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone, if (ACPI_FAILURE(status)) return -EIO; - *temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET); + /* + * Thermal hysteresis represents a temperature difference. + * Kelvin and Celsius have same degree size. So the + * conversion here between tenths of degree Kelvin unit + * and Milli-Celsius unit is just to multiply 100. + */ + *temp = hyst * 100; return 0; } -- 2.39.5