From f37fabb8643eaf8e3b613333a72f683770c85eca Mon Sep 17 00:00:00 2001 From: Krzysztof Kozlowski Date: Tue, 22 Nov 2016 19:22:44 +0200 Subject: [PATCH] thermal: hwmon: Properly report critical temperature in sysfs In the critical sysfs entry the thermal hwmon was returning wrong temperature to the user-space. It was reporting the temperature of the first trip point instead of the temperature of critical trip point. For example: /sys/class/hwmon/hwmon0/temp1_crit:50000 /sys/class/thermal/thermal_zone0/trip_point_0_temp:50000 /sys/class/thermal/thermal_zone0/trip_point_0_type:active /sys/class/thermal/thermal_zone0/trip_point_3_temp:120000 /sys/class/thermal/thermal_zone0/trip_point_3_type:critical Since commit e68b16abd91d ("thermal: add hwmon sysfs I/F") the driver have been registering a sysfs entry if get_crit_temp() callback was provided. However when accessed, it was calling get_trip_temp() instead of the get_crit_temp(). Fixes: e68b16abd91d ("thermal: add hwmon sysfs I/F") Cc: Signed-off-by: Krzysztof Kozlowski Signed-off-by: Zhang Rui --- drivers/thermal/thermal_hwmon.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/drivers/thermal/thermal_hwmon.c b/drivers/thermal/thermal_hwmon.c index 8c45de6a9140..541af5946203 100644 --- a/drivers/thermal/thermal_hwmon.c +++ b/drivers/thermal/thermal_hwmon.c @@ -98,7 +98,7 @@ temp_crit_show(struct device *dev, struct device_attribute *attr, char *buf) int temperature; int ret; - ret = tz->ops->get_trip_temp(tz, 0, &temperature); + ret = tz->ops->get_crit_temp(tz, &temperature); if (ret) return ret; -- 2.39.5