]> git.karo-electronics.de Git - karo-tx-linux.git/commitdiff
Merge remote-tracking branch 'regulator/fix/palmas' into regulator-linus
authorMark Brown <broonie@linaro.org>
Mon, 30 Sep 2013 11:04:31 +0000 (12:04 +0100)
committerMark Brown <broonie@linaro.org>
Mon, 30 Sep 2013 11:04:31 +0000 (12:04 +0100)
drivers/regulator/palmas-regulator.c

index 488dfe7ce9a6c048a751029451df59d6f6f2c074..7e2b165972e6edd6e3eee6b26478cb263db5d048 100644 (file)
@@ -201,13 +201,7 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
 #define SMPS_CTRL_MODE_ECO             0x02
 #define SMPS_CTRL_MODE_PWM             0x03
 
-/* These values are derived from the data sheet. And are the number of steps
- * where there is a voltage change, the ranges at beginning and end of register
- * max/min values where there are no change are ommitted.
- *
- * So they are basically (maxV-minV)/stepV
- */
-#define PALMAS_SMPS_NUM_VOLTAGES       117
+#define PALMAS_SMPS_NUM_VOLTAGES       122
 #define PALMAS_SMPS10_NUM_VOLTAGES     2
 #define PALMAS_LDO_NUM_VOLTAGES                50
 
@@ -979,6 +973,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
                        pmic->desc[id].min_uV = 900000;
                        pmic->desc[id].uV_step = 50000;
                        pmic->desc[id].linear_min_sel = 1;
+                       pmic->desc[id].enable_time = 500;
                        pmic->desc[id].vsel_reg =
                                        PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
                                                palmas_regs_info[id].vsel_addr);
@@ -997,6 +992,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
                                pmic->desc[id].min_uV = 450000;
                                pmic->desc[id].uV_step = 25000;
                        }
+
+                       /* LOD6 in vibrator mode will have enable time 2000us */
+                       if (pdata && pdata->ldo6_vibrator &&
+                               (id == PALMAS_REG_LDO6))
+                               pmic->desc[id].enable_time = 2000;
                } else {
                        pmic->desc[id].n_voltages = 1;